Ship Atmospheric Pressure Water Tube Boiler

  • Offshore price : $20000-$100000 Get a quote on the right form
  • Minimum order quantity : 1 set :Ship Atmospheric Pressure Water Tube Boiler
  • Supply Capacity : 10 units/month :Ship Atmospheric Pressure Water Tube Boiler
  • Manufacturer/Brand : Fangkuai boiler
  • Port : Anyang
  • payment terms : Letter of Credit, Wire Transfer, VISA

Leave Your Message And Get Price!

I need the quotation of , the fuel is , this capacity is , use for . My Name is , my Email is , my WhatsApp is , Please Send the detail information for me!

Popular products

HOT

θrion Gas Fired Steam Boiler

Capacity:1-20t/h

Rated thermal efficiency: 100-104%

Fixed working pressure: ≤1.6MPa

Applicable fuel:natural gas etc.

consult
HOT

Gas(oil) Fired Integrated Hot Water Boiler

Capacity:0.7-14MW

Rated thermal efficiency:96-98%

Fixed working pressure:≤1.25MPa

Applicable fuel:Natural gas, light oil, etc.

consult
HOT

H6 Gas Fired Hot Water Boiler

Capacity:0.7-2.8Mw

Rated thermal efficiency: 97.2-106%

Fixed working pressure:0.1MPa

Applicable fuel:Natural gas, etc.

consult
HOT

T7 Vacuum Hot Water Boilerr

Capacity:2.8-7.0Mw

Rated thermal efficiency:≥105.5%

Fixed working pressure:-0.02MPa

Applicable fuel:Natural gas, etc.

consult
HOT

V6 Gas Fired Hot Water Boiler

Capacity:99Kw

Rated thermal efficiency:97.2-104.4%

Fixed working pressure:1.0MPa

Applicable fuel:Natural gas, etc.

consult
HOT

Electric Steam Boiler

Capacity:0.5-4.0 t/h

Rated thermal efficiency:98%

Fixed working pressure:≤1.25MPa

Applicable fuel:electric energy

consult

Leave us a message

We will send out plans and quotations within five minutes

Name (optional)

Email

Whatsapp

Choose product type

Message

boilermanufactory

Get display discount

boiler
Contact us

Global Sales Hotline:
0086-371-60922096

Email: [email protected]

Voicemail
  • What is boiler | Types of boiler | How does a steam boiler

    Jan 15, 2019 · What is boiler? It is an enclosed pressure vessel in which water is converted into steam by gaining heat from any source (coal, oil, gas etc). Boiler in thermal power plant accumulates the steam and build up a pressure to expend it in turbine and convert thermal energy to mechanical energy. The generator which is connected to turbine converts the mechanical …Get Price

  • Fresh water Generator Working Principle ? Types, Uses

    May 12, 2020 · The crew consumes an average 100 liter/head/day. In a steam ship (a ship whose main propulsion unit is a turbine or a ship which could be a giant tanker with turbine-driven oil pumps) the boiler consumption may be as high as thirty tons per day.. The equipment used on board to generate freshwater from seawater is known as a freshwater generator.Get Price

  • Second Law of Thermodynamics Questions and Answers | …

    An ideal Rankine cycle with water as working fluid operates between pressure limits of 17.5 MPa in the boiler and 30 kPa in the condencer. (a) What …Get Price

  • Fresh water Generator Working Principle ? Types, Uses

    May 12, 2020 · The crew consumes an average 100 liter/head/day. In a steam ship (a ship whose main propulsion unit is a turbine or a ship which could be a giant tanker with turbine-driven oil pumps) the boiler consumption may be as high as thirty tons per day.. The equipment used on board to generate freshwater from seawater is known as a freshwater generator.Get Price

  • (PDF) Report on "Steam Power Plant" | Saddam Hussain Sohag

    For the same output the outer shell of fire tube boilers is much larger than the shell of water-tube boiler. Water tube boilers require less weight of metal for a given size, are less liable to explosion, produce higher pressure, are accessible and can respond quickly to change in steam demand.Get Price

  • KEY COMPONENTS OF BOILERS | Boilers Guide

    For example, if the event pressure in the boiler exceeds the pressure limit setting, the fuel valve is closed to prevent an unsafe, high pressure condition. The safety circuit of a flame safeguard control system typically includes switch contacts for low water cutoff, high limits, air providing switches, redundant safety and operating controls Get Price

  • Low Alloy Steel - an overview | ScienceDirect Topics

    The conventional low-alloyed steels have still been used in boiler components operated under subcritical, supercritical, and ultra-supercritical pressure boiler up to the metal temperature of approximately 580°C. However, the allowable stresses are given to the temperature through to 650°C at maximum for 2.25Cr-1Mo steel, for example.Get Price

  • KEY COMPONENTS OF BOILERS | Boilers Guide

    For example, if the event pressure in the boiler exceeds the pressure limit setting, the fuel valve is closed to prevent an unsafe, high pressure condition. The safety circuit of a flame safeguard control system typically includes switch contacts for low water cutoff, high limits, air providing switches, redundant safety and operating controls Get Price

  • (PDF) Report on "Steam Power Plant" | Saddam Hussain Sohag

    For the same output the outer shell of fire tube boilers is much larger than the shell of water-tube boiler. Water tube boilers require less weight of metal for a given size, are less liable to explosion, produce higher pressure, are accessible and can respond quickly to change in steam demand.Get Price

  • Boiler - Wikipedia

    Fire-tube boiler Here, water partially fills a boiler barrel with a small volume left above to accommodate the steam (steam space).This is the type of boiler used in nearly all steam locomotives.The heat source is inside a furnace or firebox that has to be kept permanently surrounded by the water in order to maintain the temperature of the heating surface below the …Get Price

  • (PDF) Report on "Steam Power Plant" | Saddam Hussain Sohag

    For the same output the outer shell of fire tube boilers is much larger than the shell of water-tube boiler. Water tube boilers require less weight of metal for a given size, are less liable to explosion, produce higher pressure, are accessible and can respond quickly to change in steam demand.Get Price

  • Economics | PDF | Heat Transfer - Scribd

    What is the atmospheric pressure? The water leaves the boiler tube at 50 bar and 700oK at velocity of 100 m/s. Calculate the inlet volume flow A throttling calorimeter is connected to the desuperheated steam line supplying the steam to the auxiliary feed pump on a ship. The line pressure measures 2.5 MPa.Get Price

  • Boiler - Wikipedia

    Fire-tube boiler Here, water partially fills a boiler barrel with a small volume left above to accommodate the steam (steam space).This is the type of boiler used in nearly all steam locomotives.The heat source is inside a furnace or firebox that has to be kept permanently surrounded by the water in order to maintain the temperature of the heating surface below the …Get Price

  • Second Law of Thermodynamics Questions and Answers | …

    An ideal Rankine cycle with water as working fluid operates between pressure limits of 17.5 MPa in the boiler and 30 kPa in the condencer. (a) What …Get Price

  • Fresh water Generator Working Principle ? Types, Uses

    May 12, 2020 · The crew consumes an average 100 liter/head/day. In a steam ship (a ship whose main propulsion unit is a turbine or a ship which could be a giant tanker with turbine-driven oil pumps) the boiler consumption may be as high as thirty tons per day.. The equipment used on board to generate freshwater from seawater is known as a freshwater generator.Get Price

  • Second Law of Thermodynamics Questions and Answers | …

    An ideal Rankine cycle with water as working fluid operates between pressure limits of 17.5 MPa in the boiler and 30 kPa in the condencer. (a) What …Get Price

  • Boiler - Wikipedia

    Fire-tube boiler Here, water partially fills a boiler barrel with a small volume left above to accommodate the steam (steam space).This is the type of boiler used in nearly all steam locomotives.The heat source is inside a furnace or firebox that has to be kept permanently surrounded by the water in order to maintain the temperature of the heating surface below the …Get Price

  • Economics | PDF | Heat Transfer - Scribd

    What is the atmospheric pressure? The water leaves the boiler tube at 50 bar and 700oK at velocity of 100 m/s. Calculate the inlet volume flow A throttling calorimeter is connected to the desuperheated steam line supplying the steam to the auxiliary feed pump on a ship. The line pressure measures 2.5 MPa.Get Price

  • What is boiler | Types of boiler | How does a steam boiler

    Jan 15, 2019 · What is boiler? It is an enclosed pressure vessel in which water is converted into steam by gaining heat from any source (coal, oil, gas etc). Boiler in thermal power plant accumulates the steam and build up a pressure to expend it in turbine and convert thermal energy to mechanical energy. The generator which is connected to turbine converts the mechanical …Get Price

  • What is boiler | Types of boiler | How does a steam boiler

    Jan 15, 2019 · What is boiler? It is an enclosed pressure vessel in which water is converted into steam by gaining heat from any source (coal, oil, gas etc). Boiler in thermal power plant accumulates the steam and build up a pressure to expend it in turbine and convert thermal energy to mechanical energy. The generator which is connected to turbine converts the mechanical …Get Price

  • KEY COMPONENTS OF BOILERS | Boilers Guide

    For example, if the event pressure in the boiler exceeds the pressure limit setting, the fuel valve is closed to prevent an unsafe, high pressure condition. The safety circuit of a flame safeguard control system typically includes switch contacts for low water cutoff, high limits, air providing switches, redundant safety and operating controls Get Price

  • Economics | PDF | Heat Transfer - Scribd

    What is the atmospheric pressure? The water leaves the boiler tube at 50 bar and 700oK at velocity of 100 m/s. Calculate the inlet volume flow A throttling calorimeter is connected to the desuperheated steam line supplying the steam to the auxiliary feed pump on a ship. The line pressure measures 2.5 MPa.Get Price

Discount
7X24 Online