Steam Boiler 600 Kg Operating Pressure 10 Kg

  • Offshore price : $20000-$100000 Get a quote on the right form
  • Minimum order quantity : 1 set :Steam Boiler 600 Kg Operating Pressure 10 Kg
  • Supply Capacity : 10 units/month :Steam Boiler 600 Kg Operating Pressure 10 Kg
  • Manufacturer/Brand : Fangkuai boiler
  • Port : Anyang
  • payment terms : Letter of Credit, Wire Transfer, VISA

Leave Your Message And Get Price!

I need the quotation of , the fuel is , this capacity is , use for . My Name is , my Email is , my WhatsApp is , Please Send the detail information for me!

Popular products

HOT

θrion Gas Fired Steam Boiler

Capacity:1-20t/h

Rated thermal efficiency: 100-104%

Fixed working pressure: ≤1.6MPa

Applicable fuel:natural gas etc.

consult
HOT

Gas(oil) Fired Integrated Hot Water Boiler

Capacity:0.7-14MW

Rated thermal efficiency:96-98%

Fixed working pressure:≤1.25MPa

Applicable fuel:Natural gas, light oil, etc.

consult
HOT

H6 Gas Fired Hot Water Boiler

Capacity:0.7-2.8Mw

Rated thermal efficiency: 97.2-106%

Fixed working pressure:0.1MPa

Applicable fuel:Natural gas, etc.

consult
HOT

T7 Vacuum Hot Water Boilerr

Capacity:2.8-7.0Mw

Rated thermal efficiency:≥105.5%

Fixed working pressure:-0.02MPa

Applicable fuel:Natural gas, etc.

consult
HOT

V6 Gas Fired Hot Water Boiler

Capacity:99Kw

Rated thermal efficiency:97.2-104.4%

Fixed working pressure:1.0MPa

Applicable fuel:Natural gas, etc.

consult
HOT

Electric Steam Boiler

Capacity:0.5-4.0 t/h

Rated thermal efficiency:98%

Fixed working pressure:≤1.25MPa

Applicable fuel:electric energy

consult

Leave us a message

We will send out plans and quotations within five minutes

Name (optional)

Email

Whatsapp

Choose product type

Message

boilermanufactory

Get display discount

boiler
Contact us

Global Sales Hotline:
0086-371-60922096

Email: [email protected]

Voicemail
  • Boiler (power generation) - Wikipedia

    A boiler or steam generator is a device used to create steam by applying heat energy to water.Although the definitions are somewhat flexible, it can be said that older steam generators were commonly termed boilers and worked at low to medium pressure (7–2,000 kPa or 1–290 psi) but, at pressures above this, it is more usual to speak of a steam generator.Get Price

  • 600+ TOP Mechanical Engineering Interview Questions & Answers

    Boiler tubes, usually are made from carbon steel and are subject to (a) high rates of heat transfer, (b) bending stresses due to uneven heating, especially at expanded or welded joints into headers or drums, (c) external erosion from burners and flue gas, (d) possible corrosion on the boiler side, and (e) occasional manufacturing defects.Get Price

  • Boiler Presentation - SlideShare

    Jun 21, 2012 · Boiler Presentation 1. By- Mukesh Jha Sr.Engineer -Projects, a2z Powercom Pvt.Ltd. 2. Boiler- As per "THE INDIAN BOILERS(AMENDMENT ) ACT2007 A 'Boiler' means a pressure vessel in which steam is generated for use external to itself by application of heat which is wholly or partly under pressure when steam is shut off but does not include a pressure …Get Price

  • Boiler - Wikipedia

    Q, rate of steam flow in kg/h Hg, enthalpy of saturated steam in kcal/kg Hf, enthalpy of feed water in kcal/kg q, rate of fuel use in kg/h GCV, gross calorific value in kcal/kg (e.g., pet coke 8200 kcal/kg) Heat-loss method (or, indirect method) To measure the boiler efficiency in indirect method, parameter like these are neededGet Price

  • Installation, Operating and Servicing Instructions

    Weight (kg) 15 15 18 18 15 16 17 15 Power rating(kW) 3 4.5 6 6 3 3 3 3 Current rating (A) 13 20 26 26 13 13 13 13 base of the boiler and the other end to the mains supply via an accessible isolating Do not use a water jet or steam cleaner, and do not immerse this appliance.Get Price

  • Engineering Thermodynamics: Problems and Solutions, Chapter-9

    The remaining steam continues to expand to 6 kPa. Steam is then condensed at constant pressure and pumped to the boiler pressure of 8 MPa. Steam leaves the process heater as a saturated liquid at 500 kPa. The mass flow rate of steam through the boiler is 20 kg/s.Determine (a) the rate of process heat supply and (b) the net power developed.Get Price

  • Package Boilers, Watertube Boilers, Utility Boilers - John

    Steam output from the Torripac boiler range is from 1 000 kg/h to 13 000 kg/h. Design pressures of up to 32 bar are available to be used in conjunction with saturated steam screw expanders for cogeneration applications.Get Price

  • Engineering Thermodynamics: Problems and Solutions, Chapter-9

    The remaining steam continues to expand to 6 kPa. Steam is then condensed at constant pressure and pumped to the boiler pressure of 8 MPa. Steam leaves the process heater as a saturated liquid at 500 kPa. The mass flow rate of steam through the boiler is 20 kg/s.Determine (a) the rate of process heat supply and (b) the net power developed.Get Price

  • (PDF) Report on "Steam Power Plant" | Saddam Hussain Sohag

    In order to return the steam to the high-pressure of the boiler to continue the cycle, the low- pressure steam leaving the turbine at state 2 is first condensed to a liquid at state 3 and then pressurized in a pump to state 4. For a thermal power plant the range of pressure may vary from 10 kg/cm2 to super critical pressures and the range Get Price

  • Boiler - Wikipedia

    Q, rate of steam flow in kg/h Hg, enthalpy of saturated steam in kcal/kg Hf, enthalpy of feed water in kcal/kg q, rate of fuel use in kg/h GCV, gross calorific value in kcal/kg (e.g., pet coke 8200 kcal/kg) Heat-loss method (or, indirect method) To measure the boiler efficiency in indirect method, parameter like these are neededGet Price

  • ME 200 Thermodynamics 1 Fall 2017 – Exam 3

    Mass flow rate of steam through the boiler: 3 32 kJ 420 10 s kJ 3675 46.3 kg boiler steam Q m hh kg 115.7 steam s m (b) Mass balance for the turbine: mm m 34 steam Energy balance for the actual turbine: 34 kJ kJ 3675 2270 1405 actual kg kg whh For the isentropic process through the turbine: 34 kJ 7.3710 s kg-K ss sf,10 C < s4s < sg,10 C Get Price

  • Boiler – Fundamentals and Best Practices

    Steam m3/kg 0 100.00 419.04 2257.00 2676.00 1.673 1 120.42 505.60 2201.10 2706.70 0.881 great deal as the boiler pressure increase The boiling point (b.p.) increases as the Boiler Operating Costs. Effective Internal Boiler Water Treatment ControlsGet Price

  • Complete Combustion - an overview | ScienceDirect Topics

    Notice that for each kg of fuel entering combustion, there is 16.7 kg of air required as a minimum! In reality, more air than this must be supplied, since some excess air is required to insure complete combustion.For natural gas, an efficient boiler would use about 15 percent excess air, or roughly 19 kg per kg of fuel.Get Price

  • INCREASING THE ENERGY EFFICIENCY OF BOILER AND HEATER

    Example: Consider a 23 t/h boiler operating at 860 kPa (about 50 000 lb./h at 125 psig). The blowdown water contains 770 kJ/kg (330 Btu/lb.). If the continuous blowdown system is set at the usual five percent of the maximum boiler rating, then the blowdown flow would be 1150 kg/h containing 885 500 kJ (about 2500 lb./h containing 825 000 Btu).Get Price

  • PARAT IEH High Voltage Electrode boiler - PARAT Halvorsen

    Steam Solutions The PARAT Electrode Boiler is the world leading solution for High Voltage Electrode Steam Boilers. With steam pressure range of 6 - 85 barg and capacity up to 60 MW, you have the solutions for small and large capacity steam production. This is the perfect boiler to replace your fossil fuel steam boilers with clean electrical heat.Get Price

  • Super critical boiler - SlideShare

    Aug 21, 2014 · Super critical boiler 1. SUPERCRITICAL BOILER SHIVAJI CHOUDHURY 2. What is SUPER CRITICAL The term "supercritical" refers to main steam operating conditions, being above the critical pressure of water (221. bar). Above the critical pressure there is no distinction between steam and water, i.e. above 221. bar, water is a fluid.Get Price

  • Boiler – Fundamentals and Best Practices

    Steam m3/kg 0 100.00 419.04 2257.00 2676.00 1.673 1 120.42 505.60 2201.10 2706.70 0.881 great deal as the boiler pressure increase The boiling point (b.p.) increases as the Boiler Operating Costs. Effective Internal Boiler Water Treatment ControlsGet Price

  • (PDF) Report on "Steam Power Plant" | Saddam Hussain Sohag

    In order to return the steam to the high-pressure of the boiler to continue the cycle, the low- pressure steam leaving the turbine at state 2 is first condensed to a liquid at state 3 and then pressurized in a pump to state 4. For a thermal power plant the range of pressure may vary from 10 kg/cm2 to super critical pressures and the range Get Price

  • Package Boilers, Watertube Boilers, Utility Boilers - John

    Steam output from the Torripac boiler range is from 1 000 kg/h to 13 000 kg/h. Design pressures of up to 32 bar are available to be used in conjunction with saturated steam screw expanders for cogeneration applications.Get Price

  • Super critical boiler - SlideShare

    Aug 21, 2014 · Super critical boiler 1. SUPERCRITICAL BOILER SHIVAJI CHOUDHURY 2. What is SUPER CRITICAL The term "supercritical" refers to main steam operating conditions, being above the critical pressure of water (221. bar). Above the critical pressure there is no distinction between steam and water, i.e. above 221. bar, water is a fluid.Get Price

  • Complete Combustion - an overview | ScienceDirect Topics

    Notice that for each kg of fuel entering combustion, there is 16.7 kg of air required as a minimum! In reality, more air than this must be supplied, since some excess air is required to insure complete combustion.For natural gas, an efficient boiler would use about 15 percent excess air, or roughly 19 kg per kg of fuel.Get Price

  • INCREASING THE ENERGY EFFICIENCY OF BOILER AND HEATER

    Example: Consider a 23 t/h boiler operating at 860 kPa (about 50 000 lb./h at 125 psig). The blowdown water contains 770 kJ/kg (330 Btu/lb.). If the continuous blowdown system is set at the usual five percent of the maximum boiler rating, then the blowdown flow would be 1150 kg/h containing 885 500 kJ (about 2500 lb./h containing 825 000 Btu).Get Price

  • Boiler (power generation) - Wikipedia

    A boiler or steam generator is a device used to create steam by applying heat energy to water.Although the definitions are somewhat flexible, it can be said that older steam generators were commonly termed boilers and worked at low to medium pressure (7–2,000 kPa or 1–290 psi) but, at pressures above this, it is more usual to speak of a steam generator.Get Price

  • Boiler Presentation - SlideShare

    Jun 21, 2012 · Boiler Presentation 1. By- Mukesh Jha Sr.Engineer -Projects, a2z Powercom Pvt.Ltd. 2. Boiler- As per "THE INDIAN BOILERS(AMENDMENT ) ACT2007 A 'Boiler' means a pressure vessel in which steam is generated for use external to itself by application of heat which is wholly or partly under pressure when steam is shut off but does not include a pressure …Get Price

  • ME 200 Thermodynamics 1 Fall 2017 – Exam 3

    Mass flow rate of steam through the boiler: 3 32 kJ 420 10 s kJ 3675 46.3 kg boiler steam Q m hh kg 115.7 steam s m (b) Mass balance for the turbine: mm m 34 steam Energy balance for the actual turbine: 34 kJ kJ 3675 2270 1405 actual kg kg whh For the isentropic process through the turbine: 34 kJ 7.3710 s kg-K ss sf,10 C < s4s < sg,10 C Get Price

  • Board Exam1 | PDF | Enthalpy | Pressure

    During a test on an oil-fierd boiler the folling data were recorded: Pressure of steam 2.5 MPa Temperature of steam 300 ºC Mass of feedwater entering the Boiler 11350 kg/hr Temperature of Feedwater 100 ºC Mass of fuel burned 875 kg/hr Calorific value 42.3 MJ/kg Steam at (25 bar) 2.5 MPa, 300 ºC h = 3010 kJ/kg Water at 100 ºC h = 419.10 kJ Get Price

Discount
7X24 Online